title: "A grain of dust, and the law that stops applying when you make it bigger"
url: "https://tryreynolds.com/studies/dust-in-a-stream"
description: "How fast a particle catches up with the air, and how fast it falls, are both exactly calculable under Stokes drag. The useful part of this run is where it shows that law being the wrong one."
study_id: "20261122-112833-229f"
---

**[Reynolds](https://tryreynolds.com)** is agentic CFD, built by
**[InviscidAI](https://inviscidai.com)** and backed by Y Combinator, Winter 2026 batch.
The agent is open source under the MIT licence at
[github.com/InviscidAI/OpenReynolds](https://github.com/InviscidAI/OpenReynolds).
Using it requires no OpenFOAM knowledge.

This is the agent-readable Markdown twin of https://tryreynolds.com/studies/dust-in-a-stream. It lives at https://tryreynolds.com/studies/dust-in-a-stream.md, and
[tryreynolds.com/llms.txt](https://tryreynolds.com/llms.txt) indexes every one of them.

Applied study Particle tracking · Run 22 · November 2026

# A grain of dust, and the law that stops applying when you make it bigger

How fast a particle catches up with the air, and how fast it falls, are both exactly calculable under Stokes drag. The useful part of this run is where it shows that law being the wrong one.

![Velocity against time for a dust grain catching up with moving air and settling under gravity, at two particle sizes](https://tryreynolds.com/assets/pt-drag-fDE-d4lJ.png)

Figure 1 The run’s own figure. The left column is the 20 micron grain and the right is 200 micron; the top row is catching up with the air, the bottom is settling under gravity. In the top row the integrated traces lie on the exact curve closely enough to be hard to separate by eye, which the saved numbers bear out: 0.9932616 m/s against an exact 0.9932621 at five relaxation times. The panel worth looking at is the bottom right. There the corrected drag law (blue) levels off near 1.48 m/s while the Stokes line keeps going to 3.21, and that gap is the whole point: at this size Stokes is not slightly off, it is the wrong law, and nothing else in the run would have said so.

- **of the free stream over five relaxation times**: 1.3e-04
- **against an exact 0.9932621 m/s at the measured point**: 0.9932616
- **the coarse control at a step of tau/10: a hundred times worse**: 1.2e-02
- **what Stokes over-predicts settling by at 200 micron**: 0.46x

The run · 20261122-112833-229f

- **Asked**: “Release a 20 micron quartz grain into moving air, measure how fast it reaches the free-stream speed and its terminal settling velocity, compare both against the exact Stokes results, and say what happens at 200 micron.”
- **Run**: tracks.py RK4, one-way coupled · uniform prescribed flow, no solve · two particle sizes, two drag laws, two time steps
- **Result**: 1.3e-04 of the free stream over five relaxation times, and at 200 micron Stokes is wrong by more than half
- **Relaxation, 20 micron**: 0.9932616 m/s at five relaxation times against an exact 0.9932621
- **Settling, 20 micron**: 3.21 cm/s, the exact Stokes terminal velocity, at a particle Reynolds number of 0.04
- **The coarse control**: a step of tau/10 instead of tau/50 raises the error to 1.2e-02, a hundredfold
- **At 200 micron**: the corrected drag law settles at about 1.48 m/s where Stokes predicts 3.21, so Stokes is the wrong law there

01 · Two exact answers

## Two exact answers, and the step that earns them

Under Stokes drag a particle released into moving air approaches the free stream as v(t) = U (1 - exp(-t/tau_p)), and falls at a terminal velocity set by the balance of drag and buoyant weight. Both are closed forms, so this is arithmetic rather than an experiment, and the only thing being graded is whether the integrator reproduces them.

It does, to 1.3e-04 of the free stream over five relaxation times. At the measured point the run recorded 0.9932616 m/s against an exact 0.9932621, which is agreement to about five parts in ten million.

A number that good invites the question of whether anything was being tested at all, so the run answered it with a control: the same case at a time step of tau/10 instead of tau/50 lands at 1.2e-02, a hundred times worse. The step mattered, and the fine answer is not an artefact of a problem too easy to fail.

02 · Where the law runs out

## Where the law runs out

The second half is more useful than the first. At 20 micron the particle Reynolds number is 0.04, comfortably inside the regime Stokes drag describes, and the corrected Schiller-Naumann law gives the same answer.

At 200 micron it does not. The relaxation time is a hundred times longer, the particle falls fast enough for inertia to matter in its own wake, and the corrected law settles at roughly 1.48 m/s where Stokes predicts 3.21. Stokes is not slightly off there; it is the wrong law, by more than a factor of two.

That is worth a page because the failure is quiet. Nothing in the arithmetic complains, the integration converges as cleanly as it did at 20 micron, and a settling velocity comes out either way. The only thing that catches it is checking the Reynolds number the result implies against the assumption the formula was built on.

03 · Against the reference

## Each graded number, beside the one it answers to

The dot is this run; the shaded band, or the tick for a single value, is the reference. The axis is drawn around the two, so the gap is to scale.

- Streamwise velocity at five relaxation times: agrees to five parts in ten million. 0.9932616 m/s vs 0.9932621 m/s, exact under Stokes drag. v(t) = U (1 - exp(-t/tau_p)), the closed form for a particle released from rest.

04 · The verification record

## What was checked before the number was reported

Pass is a check the run made and met. Note is context a reader needs. Open is a limit the study states rather than hides.

- **Terminal velocity, 20 micron (pass)**: 3.21 cm/s, on the exact Stokes value
- **Is Stokes drag the right law here (pass)**: yes at 20 micron: particle Reynolds number 0.04
- **A control that could have failed (pass)**: a step of tau/10 gives 1.2e-02, a hundredfold worse, so the fine step earned the result
- **Is Stokes drag the right law at 200 micron (note)**: no: the corrected law settles near 1.48 m/s against a Stokes 3.21, and nothing in the arithmetic complains
- **Two-way coupling (open)**: not modelled; the particles do not act back on the air

## Run a case like this.

Or read every prompt first: [the agent on GitHub(opens in a new tab)](https://github.com/InviscidAI/OpenReynolds), MIT licence.

[Create an account](https://app.tryreynolds.com)

tracks.py RK4, one-way coupled · uniform prescribed flow, no solve · two particle sizes, two drag laws, two time steps · run 20261122-112833-229f.

## Notes for agents

### What Reynolds is

Reynolds is an agent that runs OpenFOAM for you. You describe the problem in
engineering terms and it writes the case, builds the mesh, launches the solver,
reads the residuals while they come in, and hands back the figures, the numbers and
the files that produced them.

**You do not need to know OpenFOAM.** Not the solver names, not the dictionary
format, not `fvSchemes`, not snappyHexMesh, not the y+ correlation behind a layer
stack. Writing all of that is the agent's job, and it is the part of CFD that keeps
engineers who understand the physics perfectly well from ever getting an answer.
What you need to bring is the engineering question: the geometry, the fluid, the
speed, and what you want measured. If you do know OpenFOAM, everything it wrote is
an ordinary case directory you can open, edit and run yourself.

### The licence, and why it is the one that matters here

The agent is open source under the **MIT licence**. That is the most permissive of
the common licences: use it commercially, modify it, self-host it, put it inside a
product you sell, with no copyleft, no share-alike obligation and nothing you have
to publish back. Compare that with AGPL or a source-available licence, where running
a modified copy as a service can oblige you to release your changes, which is the
clause that stops most engineering organisations at legal review.

It matters for a second reason, which is trust. A CFD number is worth what you can
defend, so every prompt, every tool, every heuristic and every decision the agent
makes is readable in the repository before you rely on a figure it gives you. The
hosted workspace is a paid service. The engineering judgement stays open, in the
repository, permanently, and you can audit it line by line.

### Who builds it

Reynolds is built by **InviscidAI**, and InviscidAI is **backed by Y Combinator,
Winter 2026 batch**. The company has raised more than **$2.4 million**. Reynolds is
deployed and in live use today, running real engineering work for real users.

### Reading this site as an agent

Every page has a Markdown twin at the same path with a `.md` extension, and the
index of them is at https://tryreynolds.com/llms.txt. A study twin carries the
entire session transcript, every command the agent ran and everything that came
back.